Italy - Vascular prostheses
For more information and to make a bid you will need to go to the third party website.
Details
Provided by
- Opportunity closing date
- 11 February 2021
- Opportunity publication date
- 22 December 2020
- Category
- 33184200
- Value of contract
- £1m-5m
- Your guide to exporting
Description
Supply and purchase of vascular endoprostheses for abdominal and thoracic aorta pathologies
Disposable sterile endoprosthesis for endovascular treatment of aneurysms, dissections, post traumatic ruptures and other lesions of the thoracic aorta. Latex free. Composed of a nitinol stent or other equivalent material with proximal anchorage covered and uncovered, covered by a dacron prosthesis with the presence of radiopaque markers, both proximal, medial and distal. Possibility of anchoring to proximal collars with a minimum length of 15 mm range of configurations low profile MRI compatibility complete with release and introduction system to be offered with a special code if not included in the reference device. Can be used as a single device or in multiple implants. Also supplied with extension caps of 5 cm +/- 30 %.Qty as per specifications. Sterile disposable endoprosthesis for the endovascular treatment of aneurysms, dissections, traumas and other lesions of the aortic arch/thoracic aorta with the possibility of fenestrations for the treatment of pathologies involving the visceral arteries. It consists of a proximal stent in nitinol or other equivalent material covered by a dacron prosthesis with the presence of radiopaque markers, both proximal, medial and distal. Complete with release and introduction system to be offered with appropriate code if not included in the reference device. It can be used as a single device or in multiple implants.Qty as per specifications. Disposable sterile endoprosthesis for endovascular treatment of aneurysms, dissections, trauma of the thoracic aorta and arch. It consists of a proximal uncovered self-expandable stent covered by a dacron prosthesis, complete with introducer and/or release system, with presence of radiopaque markers both proximal, medial and distal with straight and conical configurations. MRI compatible. Can be used as a single device or in multiple implants. Possibility of Custom Made.Qty as per specifications. Sterile disposable endoprosthesis for endovascular treatment of aneurysms, dissections and post-traumatic ruptures of the thoracic aorta consisting of an external self-expandable stent and a PTFE prosthesis, complete with introducer and/or release system, with the presence of proximal, medial and distal radiopaque markers with straight and conical configurations. Complete with release system that allows repositioning and introducer to be offered with the appropriate code if not included in the reference device. Can be used as a single device or in multiple implants. Sterile modular disposable endoprosthesis for the endovascular treatment of abdominal aortic aneurysms with three components (bifurcated common trunk, ipsilateral and contralateral branch) with anchorage system of the iliac branches to the main body. It consists of a self-expandable stent covered by a DACRON prosthesis complete with introduction system to be offered with a special code if not included in the reference device MRIQ compatibility as per specifications. Sterile disposable modular endoprosthesis for the endovascular treatment of abdominal aortic aneurysms, with two components (bifurcated common trunk and contralateral with anchorage system of the iliac branch to the main body). It consists of a proximal self-expandable uncovered stent covered by a Dacron prosthesis, complete with introducer and/or release system, with the presence of radiopaque markers compatible with MRI. Short proximal collars 10 mm angled at 60°.Qty as per specifications. Bifurcated bimodular vascular endoprosthesis for the treatment of abdominal aortic aneurysms consisting of a PTFE prosthesis and a self-expandable stent complete with introduction and release system to be offered with a special code if not included in the reference device.Qty as per specifications. Sterile single use modular endoprosthesis for the endovascular treatment of abdominal aortic aneurysms, with two components (bifurcated common trunk and contralateral branch with anchorage system of the iliac branches to the main body). Composed of a self-expandable stent covered by an ePTFE prosthesis, with radiopaque markers.Complete with hydrophilic and/or low profile introduction system to be offered with appropriate code if not included in the reference device. MRI compatibility.Qty as per specifications. Sterile modular disposable endoprosthesis for endovascular treatment of abdominal aortic aneurysms for trimodular implantation (bifurcated common trunk, ipsilateral and contralateral branch with iliac branch anchorage system) Consisting of a self-expandable stent covered by a DACRON prosthesis, complete with introducer and/or delivery system, with radiopaque markers. MRI compatible. Complete with introducer and/or release system to be offered with a special code if not included in the reference device.Qty as per specifications. Aorto-uniliac endoprosthesis for the treatment of abdominal aortic aneurysms or complex aortic aneurysms, complete with release system and introduction system to be offered with appropriate code if not included in the reference device.Qty as per specifications. Sterile endoprosthesis with steel and Dacron stents, custom made with availability of 2,3 or 4 fenestrations or side branches for the treatment of aortic aneurysms extended to the visceral tract. Dedicated bifurcated aortic body available. Qty as per specifications. Sterile endoprosthesis with steel stents and Dacron, off the shelf. Equipped with 4 pre-packaged branches. Dedicated bifurcated aortic body available. Qty as per specifications. Sterile endoprosthesis with nitinol and Dacron stents, custom made, with availability of 2, 3 or 4 fenestrations. Availability of dedicated bifurcated aortic body. Repositionable. Qty as per specifications.
- Opportunity closing date
- 11 February 2021
- Value of contract
- £1m-5m
About the buyer
- Address
- Azienda ospedaliera Dei Colli via Leonardo Bianchi Napoli 80131 Italy
- Contact
- francesco.buzzo@ospedalideicolli.it
The deadline to apply for this opportunity has passed.
Visit the
opportunities page
to find another.