Medium and low voltage HVT:- Medium voltage switchgear 24kV air-insulated consisting of:2 pcs. cable panel EVU (loop), transfer panel, elevated panel, 2 pcs. transformer switch panel, incl. MV cabling - 22m² switchgear rooms - raised floor MSHV- room with tubular frame for the installation of the switchgear- pressure relief flap- 2 pcs. liquid-filled transformers 800kVA according to the eco-design guideline. Ökodesign-Richtlinie on transformer rails- 16m² grid floor in the transformer cells- 150m cable tray width 30-40cm- 600m single wire 240mm² as main supply line between transformer and NSHV- potential equalization MSHV and transformer cells completely- low voltage switchgear 2500A consisting of2 pcs. feed transformer with circuit breaker,1 pc. outgoing feeder no.1 EVU measurement incl. 2 pcs NH-SLS 200A incl. measuring transformer 1 pc EVU measuring field 2500A incl. measuring transformer 1 pc feed field PV 250A incl. measuring transformer 1 pc EVU measuring field 2500A incl. measuring transformer 1 pc feed field BHKW 630A incl. measuring transformer 1 pc outgoing feeder field no.2 incl. 26 pcs. NH-SLS 160-400A incl. measuring transformer 1 pc. outgoing feeder field no. 3 incl. 26 pcs. NH-SLS 160-400A incl. measuring transformer 1 pc. ZEP - meter cabinet completely removed- 25m² switch rooms - raised floor NSHV with pipe frame for the installation of the switch cabinets- 15 pcs. fire protection bulkhead in different sizes. Sizes
Medium and low voltage HVT:- Medium voltage switchgear 24kV air-insulated consisting of:2 pcs. cable panel EVU (loop), transfer panel, elevated panel, 2 pcs. transformer switch panel, incl. MV-cabling - 22m² switchgear rooms - raised floor MSHV- room with tubular frame for the installation of the switchgear- pressure relief flap- 2 pcs. liquid filled transformers 800kVA acc. Ökodesign-Richtlinie on transformer rails- 16m² grid floor in the transformer cells- 150m cable tray width 30-40cm- 600m single wire 240mm² as main supply line between transformer and NSHV- potential equalization MSHV and transformer cells completely- low voltage switchgear 2500A consisting of2 pcs. feed transformer with circuit breaker,1 pc. outgoing feeder no.1 EVU measurement incl. 2 pcs NH-SLS 200A incl. measuring transformer 1 pc EVU measuring field 2500A incl. measuring transformer 1 pc feed field PV 250A incl. measuring transformer 1 pc EVU measuring field 2500A incl. measuring transformer 1 pc feed field BHKW 630A incl. measuring transformer 1 pc outgoing feeder field no.2 incl. 26 pcs. NH-SLS 160-400A incl. measuring transformer 1 pc. outgoing feeder field no. 3 incl. 26 pcs. NH-SLS 160-400A incl. measuring transformer 1 pc. ZEP - meter cabinet completely removed- 25m² switch rooms - raised floor NSHV with pipe frame for the installation of the switch cabinets- 15 pcs. fire protection bulkhead in different sizes. Sizes

Opportunity closing date
14 July 2022
Value of contract
to be confirmed

About the buyer

Address
Stadtwerke Aalen GmbH Im Hasennest 9 Aalen 73433 Germany
Contact
kha@hitzler-ingenieure.de

The deadline to apply for this opportunity has passed.
Visit the opportunities page to find another.

Is there anything wrong with this page?