Germany - electrical installation works

For more information and to make a bid you will need to go to the third party website.

Details

Provided by Open Opps
Opportunity closing date
12 November 2019
Opportunity publication date
03 October 2019
Category
45311200: Electrical fitting work
Value of contract
to be confirmed
Your guide to exporting
Report opportunity

Description

Power:- Central battery system with 28 circuits for safety lighting,- Low-voltage main distribution,- Power supply panel EVU with transformer meter,- Outlet panel with 10 fuse elements,- Meter cabinet combination with 6 meter places,- General distributor for the general consumers of the building,- 1 x main switch as load break switch-- 1 x expansion overvoltage protection type 2, 3-pol..,1 x group FI switch 3-pin, per group with following 6 x miniature circuit breakers B16A,´-- 5 x miniature circuit breakers B16A,-- 10 x miniature circuit breakers B10A,-- 1 x group FI switch 3-pin, per group with following 6 x miniature circuit breakers B16A,-- 10 x miniature circuit breakers B10A,-- 1 x group FI switch 3-pin, per group with following 6 x miniature circuit breakers B16A,-- 5 x miniature circuit breakers B16A,-- 10 x miniature circuit breakers B10A,-- 1 x group FI switch 3-pin, per group with following 6 x miniature circuit breakers B16A,-- 10 x miniature circuit breakers B10A,-- 1 x group FI switch 3-pin, per group with following 6 x miniature circuit breakers B16A,´-- 5 x miniature circuit breaker B16A,-- 10 x miniature circuit breaker B10A,-- 1. group FI switch 3-pin, per group with following-- 2 x FI-LS B10A-- 10 x FI-LS B16A, 2-pole for individually fused circuits,-- 2 x miniature circuit breakers C25A, 3-pole -- 2 x miniature circuit breakers C16A, 3-pole -- 2 x miniature circuit breakers C16A, 3-pole ---- 2 x miniature circuit breakers B6A, 1-pin.1 x Astro clock, 2-channel- 6 pcs. floor distributor as floor distributor:-- 1 x main switch as load disconnector,-- 1 x expansion overvoltage protection type 2, 3-pin,5 x group FI switches 3-pin, per group with following,-- 6 x miniature circuit breakers B16A,-- 2 x group FI switches 3-pin, per group with following,-- 6 x miniature circuit breakers B16A,-- 2 x group FI switches 3-pin, per group with following, per group with following-- 6 x miniature circuit breakers B10A and 12x auxiliary switches for DALI bus separation,-- 1 x group FI switch 3-pin, per group with following,-- 4 x miniature circuit breakers B10A and controlled by motion detector,-- 23 x FI-LS B16A, 2-pole for individually fused sockets,-- 2 x miniature circuit breakers B20A, 3-pole for fixed connections,-- 10 x miniature circuit breakers B16A, 1-pole for jal.-Actuators,-- 10 x miniature circuit breakers B10A, 1-pin for valve actuators,-- 3 x miniature circuit breakers B6A, 1-pin for fixed connections,Power cables:Various types of installation, mainly support systems, in pipe, cavity wall in wall slots- 150 m halogen-free cable NHXMH-J 4 x 35 mm2,- 230 m halogen-free cable NHXMH-J 4 x 25 mm2,- 9 100 m ha Ca. 9100 m halogen-free cable NHXMH-J 3 x 2.5 mm2,- loop-free cable NHXMH-J 3 x 2.5 mm2,- 600 m halogen-free cable NHXMH-J 5 x 4 mm2,- 3 000 m halogen-free cable NHXMH-J 5 x 2.5 mm2,- 9 100 m halogen-free cable NHXMH-J 3 x 2.5 mm2,- 2 350 m halogen-free cable NHXMH-J 3 x 1,5 mm2,- 3 600 m halogen-free cable NHXMH-J 5 x 1,5 mm2,- 5 m NYY-J 4 x 120 mm2,- 5 m NYY-J 4 x 70 mm2,- 40 m NYY-J 4 x 50 mm2,- 400 m NYY-J 3 x 2,5 mm2 buried,- 2 500 m E30 NHXH-J 3 x 2,5 mm2.Installation devices:- 19 ceiling connection columns,- 11 pcs. floor tanks,- 20 m parapet duct,- 400 pcs. sockets uP,- 50 pcs. Circuit breaker,- 90 pcs. presence detector,- 90 pcs. KNX buttons/operating elements.lighting systems:- 200 pcs. recessed luminaires,- 16 pcs. mirror luminaires,- 30 pcs. suspended luminaires,- 120 pcs. Downlights,- 30 pcs. stairwell lights,- 50 pcs. pictogram lights,- 70 pcs. Workstation equipment: Each AP has 2 double socket outlets and 2 double data socket outletsLighting in offices is via recessed ceiling luminaires with daylight control (HCL)External lightning protection system:- 600 m catch and arrestors,- 25 pcs. Interception rods,- 400 m equipotential bonding cable.Low current systems:Time and access control system:- 2 time recording terminals,- 3 door controllers,- 100 transponders.Call system:- WC accessories call set with UPS,- 1 pc. Emergency call set server room shading system:- 1 pc. Weather central server and multimedia:- 2 pcs. IT racks with UPS,- 1 pc. IT safe (safety cell),- 5 pcs 19" wall housing with 6 HE,- 33 pcs 24-port PoE switch,- 10 pcs WLAN router,- 160 pcs. Data sockets 2 x RJ45,- 5 pcs Sat IP Receiver Low current cable:- 2 250 m J-H(St)H 4 x 2 x 0,8 Installation cable,- 2 500 m Fire alarm cable JE-H(St)H 2 x 2 x 0,8,- 3 000 m Cat. 7 Installation cable,- 4 250 m FO 4 Multimode,- 200 m FO 12 Singlemode.

Opportunity closing date
12 November 2019
Value of contract
to be confirmed

About the buyer

Address
Gebäude- und Grundstücksgesellschaft Zwickau mbH Parkstraße 4 Zwíckau 08056 Germany
Contact
info@ggz.de

The deadline to apply for this opportunity has passed.
Visit the opportunities page to find another.

Is there anything wrong with this page?